Measurement Specifications | |
|
Frequency Range | |
Bandwidth | PPA5500-HC(50Arms) : DC, 10mHz ~ 1MHz |
|
Voltage Input | |
Internal Ranges | Normal : 300mVpk ~ 3000Vpk 9 Ranges – 300mV, 1V, 3V, 10V, 30V, 100V, 300V, 1kV, 3kV (240Vrms within 300Vpk range, using 20% over range) |
Internal Accuracy | Normal : 0.01% Rdg + 0.038% Rng + (0.004%xkHz) + 5mV |
External Voltage BNC Input Ranges | 300uVpk ~ 3Vpk [BNC Connector 3Vpk Max Input] 9 Ranges – 300uV, 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V |
External Voltage Input Accuracy | 0.01% Rdg + 0.038% Rng + (0.004%xkHz) + 3uV |
|
Current Input | |
PPA55x1 50Arms Shunt, 50A Screw Type Safety Terminals | 100mApk ~ 1000Apk (50Arms) 9 Ranges – 100mA, 300mA, 1A, 3A, 10A, 30A, 100A, 300A, 1kA |
Internal Shunt Accuracy | PPA55x1 : 0.01% Rdg + 0.038% Rng + 0.004%xkHz + 900uA |
External Current BNC Input Ranges | 300uVpk ~ 3Vpk [BNC Connector 3Vpk Max Input] 9 Ranges – 300uV, 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V |
External Current Input Accuracy | 0.01% Rdg + 0.038% Rng + (0.004%/kHz) + 3uV |
|
Phase Accuracy | |
Degrees | PPA55x1(50Arms) : 0.01deg + (0.02deg/kHz) |
|
Power Accuracy | |
Normal | [0.03% + 0.03%/pf + (0.01%/kHz)/pf] Rdg + 0.03% VA Rng |
40Hz ~ 850Hz | [0.02% + 0.03%/pf + (0.01%/kHz)/pf] Rdg + 0.02% VA Rng |
|
General | |
Crest Factor | 20 (Voltage and Current) |
Sample Rate | 1Ms/s on all channels, real time No-Gap |
IEC Compliant Modes | IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12 IEC62301/EN50564 Standby Power Mode |
Application Modes | PWM Motor Drive, Harmonics and Flicker, Transformer, TTV105 (Airbus ADB0100 Inter harmonics), Ballast, Inrush, Standby Power |
|
CMRR – Common Mode Rejection Ratio | 250V @ 50Hz – ≥ 1mA (150dB) 100V @ 100kHz – ≥ 3mA (130dB) |
|
Measurement Parameters | |
| W, VA, Var, pf, V & A – rms, rectified mean, AC, DC, peak, surge, crest factor, form factor, star to delta voltage, +ve Pk, -ve Pk |
| Frequency (Hz), Phase (deg), Fundamentals, Impedance |
| Harmonics, THD, TIF, THF, TRD, TDD |
| Integrated Values, Datalog, Sum and Neutral Values |
|
Datalog | (Up to 4 user selectable measurement functions (60 with PC software) |
Datalog window | No-Gap analysis, Minimum Window 2ms |
Memory | RAM up to 10M records into flash RAM (Non Volatile) |
|
Communication Ports | RS232, LAN, USB, GPIB, Extension (Aux) |
|
Standard Accessories | |
Leads | Power, RS232, USB |
Connection Cables | 36A 1.5m long 4mm stackable terminals. 1x red, 1x yellow, 2x black per phase (1x red, 1x black per phase with HC version) |
Connection Clips | 4mm terminated alligator clips – 1x red, 1x yellow and 2x black per phase (1x red, 1x black per phase with HC version) |
Instruction manual | User manual, Communications manual |
Other documents | Calibration certificate, Quick start guide |
|
Mechanical and Environmental | |
Display | 320×240 dot full colour TFT, White LED backlit |
Dimensions | 130H x 400W x 315D mm excluding feet |
Weight | 5.4kg (1 Phase), 6kg (3 Phase) |
Safety Isolation | 1000Vrms or DC (CATII), 600Vrms or DC (CATIII) |
Power Supply | 90 ~ 265Vrms, 50 ~ 60Hz, 40VA Max |
Operating Conditions | 5 deg to 40 deg ambient temperature (or air intake temperature when rack mounted), 20-90% Non-condensing relative humidity. |